Workshop

Generator size for circular saw and small air compressor

Use the default WattSizer rule: add running watts, then model the largest startup load while the other selected loads are already running.

Running watts3,000 W
Starting watts5,300 W
Recommended size6,400 W

The peak-starting assumption is driven by Small air compressor. With the default 20% buffer, WattSizer rounds up to the next 100 watts.

ApplianceRunningStartingSource note
Circular saw1,500 W3,500 WTool motor startup can be high; default is a conservative saw nameplate planning value.
Small air compressor1,200 W3,500 WCompressor start loads are model dependent; default assumes a small portable compressor without soft start.
Two tool battery chargers300 W300 WCharger input labels vary by brand and pack count; default assumes two active fast chargers.

Try the load yourself

Edit this scenario

Running load0 W
Starting load0 W

Recommended generator0 W
LoadRunning wattsStarting watts

Power station estimate

For battery units, the selected running load needs about 0 Wh for 8 hours or 0 Wh for 12 hours before weather, battery age, and inverter losses.

Safety check

Never operate a fuel-burning generator indoors, in a garage, on a porch, or near open windows. Use a listed transfer switch or interlock installed by a qualified electrician for home wiring, and verify actual device nameplates before buying equipment.

Generator or power station?

Fuel generators are useful for motor loads and longer outages, while battery power stations are better for indoor-safe electronics and medical-device planning. For battery sizing, this selected running load is about 28,800 Wh for 8 hours with the same buffer.

Never operate a fuel-burning generator indoors, in a garage, on a porch, or near open windows. Use a listed transfer switch or interlock installed by a qualified electrician for home wiring, and verify actual device nameplates before buying equipment.